US documentation
Lab results & certificates.
Search reported measurements and original documents by product, lot or report number. See how to match a lot number.
45 latest supplier reports
Latest available reports from our US supplier for each sample specification and test panel, newest first. Printed sample labels are retained where the wording differs. These reports have not been matched to a lot allocated to a HeartPep order.
45 of 45 supplier reference reports
| Sample / lot | Reported results | Report details | Original document |
|---|---|---|---|
| ARA-290 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): ARA 290; pH (Probe): 6.59 (specification 5.0 – 8.0); Water Activity (Probe): 0.4147 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0312.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for ARA 290 10MG, PDF, opens in a new tab |
| BPC-157 5 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): BPC-157; pH (Probe): 5.90 (specification 5.0 – 8.0); Water Activity (Probe): 0.2457 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0327.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for BPC 157 5MG, PDF, opens in a new tab |
| BPC-157 / TB-500 10 mg totalFormat: not stated in reportPrinted sample: BPC/TB 500 10MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): BPC-157 + TB-500; pH (Probe): 6.38 (specification 5.0 – 8.0); Water Activity (Probe): .2687 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS Filename says5-5mg, actual sample labelBPC/TB50010MG; preserve total label, inspect component assay before declaring per-component amount. ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. Component amounts follow the component order printed in the original report. The single RP-HPLC purity value is reported for the tested blend; no separate component-purity minimum is stated. | Optiq Health Labs, LLC0325.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply The PDF sample label gives a total of 10 mg. The supplier filename says 5/5 mg; confirm component amounts before relying on that specification. | Open full report ↗ for BPC/TB 500 10MG, PDF, opens in a new tab |
| BPC-157 / TB-500 20 mg totalFormat: not stated in reportPrinted sample: BPC/TB500 20MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 5.67; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. Filename identifies 10/10mg components. Printed report title says 20mg and measured potency is total; component amounts are not established. | Optiq Health Labs LLC0311.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for BPC/TB500 20MG, PDF, opens in a new tab |
| Epithalon 50 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 5.45; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. | Optiq Health Labs LLC0303.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for EPITHALON 50MG, PDF, opens in a new tab |
| GLOW 70 mg totalFormat: not stated in reportPrinted sample: GLOW 70MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): GHK-Cu + BPC-157 + TB-500; pH (Probe): 6.21 (specification 5.0 – 8.0); Water Activity (Probe): 0.4010 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. Component amounts follow the component order printed in the original report. The single RP-HPLC purity value is reported for the tested blend; no separate component-purity minimum is stated. | Optiq Health Labs, LLC0324.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for GLOW 70MG, PDF, opens in a new tab |
| Ipamorelin 10 mgFormat: not stated in reportPrinted sample: IMPAMORELIN 10MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 5.18; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. Printed title is misspelled IMPAMORELIN; identity field is Ipamorelin. | Optiq Health Labs LLC0314.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for IMPAMORELIN 10MG, PDF, opens in a new tab |
| Kisspeptin 10 mgFormat: not stated in reportPrinted sample: KISSPETIN 10MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): Kisspeptin; pH (Probe): 6.37 (specification 5.0 – 8.0); Water Activity (Probe): 0.4209 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0313.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for KISSPETIN 10MG, PDF, opens in a new tab |
| MOTS-c 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): MOTS-c; pH (Probe): 5.27 (specification 5.0 – 8.0); Water Activity (Probe): 0.2866 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0299.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for MOTS-C 10MG, PDF, opens in a new tab |
| MOTS-c 40 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 6.24; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. | Optiq Health Labs LLC0305.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for MOTS-C 40MG, PDF, opens in a new tab |
| NAD+ 500 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): NAD+; pH (Probe): 5.32 (specification 5.0 – 8.0); Water Activity (Probe): 0.3921 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0296.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for NAD 500MG, PDF, opens in a new tab |
| PT-141 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): PT-141 (Bremelanotide); pH (Probe): 5.04 (specification 5.0 – 8.0); Water Activity (Probe): 0.4169 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0297.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for PT 141 10MG, PDF, opens in a new tab |
| Selank 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): Selank; pH (Probe): 5.51 (specification 5.0 – 8.0); Water Activity (Probe): 0.4311 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0302.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for SELANK 10MG, PDF, opens in a new tab |
| Semax 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): Semax; pH (Probe): 5.20 (specification 5.0 – 8.0); Water Activity (Probe): .3151 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0322.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for SEMAX 10MG, PDF, opens in a new tab |
| SNAP-8 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): Snap-8; pH (Probe): 5.06 (specification 5.0 – 8.0); Water Activity (Probe): 0.3673 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0315.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for SNAP 8 10MG, PDF, opens in a new tab |
| SS-31 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 5.56; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. | Optiq Health Labs LLC0307.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for SS31 10MG, PDF, opens in a new tab |
| SS-31 50 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesMultitest panel; pH 5.56; identity LC-MS identified; endotoxin LAL <=0.05 EU/mg Pass; sterility USP71 No Growth Pass; total yeast and mold USP61/62 Within Limits Pass; residual solvents GC-MS Pass; heavy metals ICP-OES Within Limits Pass. | Optiq Health Labs LLC0309.OPT.260729-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for SS31 50MG, PDF, opens in a new tab |
| TB-500 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): TB-500; pH (Probe): 5.23 (specification 5.0 – 8.0); Water Activity (Probe): 0.3752 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0320.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for TB-500 10MG, PDF, opens in a new tab |
| Thymosin Alpha 1 10 mgFormat: not stated in reportLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): Thymosin Alpha-1; pH (Probe): 5.28 (specification 5.0 – 8.0); Water Activity (Probe): 0.3077 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. | Optiq Health Labs, LLC0316.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for THYMOSIN ALPHA 1 10MG, PDF, opens in a new tab |
| AOD-9604 5 mgFormat: not stated in reportLot 2149-TSN/TSBN-112APurity |
RP-HPLC purity only; no measured mg content or microbiological result reported. | Optiq Health Labs, LLC0291.OPT.260727-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for AOD9604 5mg, PDF, opens in a new tab |
| BPC-157 10 mgFormat: not stated in reportLot 1070-TSBN/TSBN-112APurity |
RP-HPLC purity only; no measured mg content or microbiological result reported. Additional tests & notesPurity-only report. No measured content, sterility or endotoxin panel. | Optiq Health Labs LLC0292.OPT.260727-R1Certificate of analysisIssued date: Named client: Wholesale Peptide Supply | Open full report ↗ for BPC-157 10mg, PDF, opens in a new tab |
| CJC-1295 / Ipamorelin 5 mg / 5 mgFormat: not stated in reportPrinted sample: CJC/IPA 5mg/5mgLot 2157-TSN/TSBN112-APurity |
RP-HPLC purity only; no measured mg content or microbiological result reported. | Optiq Health Labs, LLC0290.OPT.260727-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for CJC/IPA 5mg/5mg, PDF, opens in a new tab |
| DSIP 10 mgFormat: not stated in reportLot 1086-TSBN/TSBN-112APurity |
RP-HPLC purity only; no measured mg content or microbiological result reported. | Optiq Health Labs, LLC0286.OPT.260727-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for DSIP 10mg, PDF, opens in a new tab |
| Ipamorelin 5 mgFormat: not stated in reportPrinted sample: IPA 5mgLot 0925-TSBN/TSBN-2309APurity |
RP-HPLC purity only; no measured mg content or microbiological result reported. | Optiq Health Labs, LLC0285.OPT.260727-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for IPA 5mg, PDF, opens in a new tab |
| 5-Amino-1MQ 50 mgFormat: not stated in reportPrinted sample: 5 AMINO 1 50MGLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.01 EU/mg (report limit 7.00 EU/mg; Pass) The analyte row reports 99.735% while the displayed Total Purity summary rounds to 99.73%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37516Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for 5 AMINO 1 50MG, PDF, opens in a new tab |
| AOD-9604 10 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.50 EU/mg, limit 35.00 EU/mg, Pass | Accurate Test LabsATL-37534Laboratory analysis reportCompleted date: Named client: Wholesale Peptide Supply | Open full report ↗ for AOD9604 10MG, PDF, opens in a new tab |
| Bacteriostatic water 10 mlFormat: not stated in reportPrinted sample: BAC WATER 10MLLot FLL-0629Benzyl alcohol and endotoxin |
Benzyl alcohol via HS-GC-MS and a separate endotoxin test. Heavy metals Not Tested. No peptide-purity, peptide-content or sterility result. Additional tests & notesBenzyl alcohol 0.90% (HS-GC-MS); heavy metals: Not Tested; Endotoxin 0.50 EU/mL (report limit 350.00 EU/mL; Pass) Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37551Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for BAC WATER 10ML, PDF, opens in a new tab |
| Cagrilintide 10 mgFormat: not stated in reportPrinted sample: CARGRILINITDE 10MGLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.05 EU/mg (report limit 35.00 EU/mg; Pass) Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37503Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for CARGRILINITDE 10MG, PDF, opens in a new tab |
| CJC-1295 with DAC 5 mgFormat: not stated in reportPrinted sample: CJC W DAC 5MGLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 1.00 EU/mg (report limit 70.00 EU/mg; Pass) The analyte row reports 99.459% while the displayed Total Purity summary rounds to 99.46%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37535Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for CJC W DAC 5MG, PDF, opens in a new tab |
| Epithalon 10 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.05 EU/mg (report limit 35.00 EU/mg; Pass) Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37515Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for EPITHALON 10MG, PDF, opens in a new tab |
| GHK-Cu 100 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.05 EU/mg, limit 3.50 EU/mg, Pass | Accurate Test LabsATL-37528Laboratory analysis reportCompleted date: Named client: Wholesale Peptide Supply | Open full report ↗ for GHK-CU 100MG, PDF, opens in a new tab |
| GHK-Cu 50 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.10 EU/mg (report limit 7.00 EU/mg; Pass) Sample label GHK-CU 50MG, quantitative result77.75mg/unit. Preserve both without assuming the marketed50mg label is independently verified by this result. The analyte row reports 99.784% while the displayed Total Purity summary rounds to 99.78%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37542Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply The sample label says 50 mg; the report lists 77.75 mg/unit. This discrepancy needs clarification before using it as batch evidence. | Open full report ↗ for GHK-CU 50MG, PDF, opens in a new tab |
| Glutathione 1500 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.02 EU/mg (report limit 0.50 EU/mg; Pass) Filename says1500mg-mL while actual sample label saysGLUTATHIONE1500MG; no concentration inferred from filename. The analyte row reports 99.346% while the displayed Total Purity summary rounds to 99.35%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37550Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply The PDF sample label gives 1500 mg. Its filename contains mg/mL, which does not establish a concentration. | Open full report ↗ for GLUTATHIONE 1500MG, PDF, opens in a new tab |
| KLOW 80 mg totalFormat: not stated in reportPrinted sample: KLOW 80mgLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): total purity summary and individual analyte amounts in mg/unit. Component purity figures are mixture proportions, not separate 99%-purity claims. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.01 EU/mg (report limit 35.00 EU/mg; Pass) Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37523Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for KLOW 80mg, PDF, opens in a new tab |
| KPV 10 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.50 EU/mg (report limit 35.00 EU/mg; Pass) The analyte row reports 99.484% while the displayed Total Purity summary rounds to 99.48%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37539Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for KPV 10MG, PDF, opens in a new tab |
| Melanotan II 10 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.50 EU/mg (report limit 35.00 EU/mg; Pass) The analyte row reports 99.914% while the displayed Total Purity summary rounds to 99.91%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37533Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for MELANOTAN II 10MG, PDF, opens in a new tab |
| NAD+ 1000 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin | Failed endotoxin specification: 2.10 EU/mg against a 0.50 EU/mg limit.
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 2.10 EU/mg, limit 0.50 EU/mg, FAIL The endotoxin panel is marked FAIL in the original report. This result applies to the submitted supplier sample; no HeartPep allocated lot is confirmed. | Accurate Test LabsATL-37555Laboratory analysis reportCompleted date: Named client: Wholesale Peptide Supply | Open full report ↗ for NAD+ 1000MG, PDF, opens in a new tab |
| Sermorelin 10 mgFormat: not stated in reportPrinted sample: SEMORELIN 10MGLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.05 EU/mg (report limit 35.00 EU/mg; Pass) The analyte row reports 99.493% while the displayed Total Purity summary rounds to 99.49%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37518Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for SEMORELIN 10MG, PDF, opens in a new tab |
| Tesamorelin 10 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.50 EU/mg (report limit 35.00 EU/mg; Pass) The analyte row reports 99.129% while the displayed Total Purity summary rounds to 99.13%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37517Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for TESAMORELIN 10MG, PDF, opens in a new tab |
| Tesamorelin 20 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.25 EU/mg, limit 17.50 EU/mg, Pass | Accurate Test LabsATL-37530Laboratory analysis reportCompleted date: Named client: Wholesale Peptide Supply | Open full report ↗ for TESAMORELIN 20MG, PDF, opens in a new tab |
| Glutathione (strength not stated)Format: not stated in reportPrinted sample: GlutathioneLot GL61526Microbiology and endotoxin |
Microbiology only. No chemical identity, purity, assay or labelled quantity. ScanRDI entry states No Method Suitability on file. Additional tests & notesScanRDI sterility Pass; USP 85 endotoxin <2 EU/mL, limit 900 EU/mL, Pass No Method Suitability on file. No exact strength, purity or content established. | Eagle Analytical Services IncETX-260615-0096Microbiology laboratory reportPrint date: Named client: FAWC The report does not establish an exact labelled quantity or formulation. | Open full report ↗ for Glutathione, PDF, opens in a new tab |
| Sermorelin (strength not stated)Format: not stated in reportPrinted sample: SermorelinLot SR52726Microbiology and endotoxin |
Microbiology only. No chemical identity, purity, assay or labelled quantity. ScanRDI entry states No Method Suitability on file. Additional tests & notesScanRDI sterility Pass; USP 85 endotoxin <2 EU/mL, limit 875 EU/mL, Pass No Method Suitability on file. No exact strength, purity or content established. | Eagle Analytical Services IncETX-260529-0461Microbiology laboratory reportPrint date: Named client: FAWC The report does not establish an exact labelled quantity or formulation. | Open full report ↗ for Sermorelin, PDF, opens in a new tab |
| IGF-LR3 (strength not stated)Format: not stated in reportPrinted sample: IGF-LR3Lot IG43026Microbiology and endotoxin |
Microbiology only. No chemical identity, purity, assay or labelled quantity. ScanRDI entry states No Method Suitability on file. Additional tests & notesScanRDI sterility: Pass; bacterial endotoxin (USP <85>): <2 EU/mL (limit 2000 EU/mL), Pass Report names FAWC, not Wholesale Peptide Supply or HeartPep. Only ScanRDI sterility and USP <85> bacterial endotoxin tests shown; no purity, chemical identity, peptide assay or labelled mass is reported. Method suitability line says No Method Suitability on file. Quantity unspecified; do not infer 1 mg from the storefront product or filename. Reported microbiology pass is specific to the tested sample. Do not turn it into a current HeartPep product sterility or suitability claim. | Eagle Analytical Services Inc.ETX-260506-0602Microbiology laboratory reportPrinted and tests completed 2026-05-11; submission number used as report identifier: Named client: FAWC Microbiology report only, with no chemical identity, purity, assay or labelled quantity. It names FAWC as the client. Method suitability is not on file. | Open full report ↗ for IGF-LR3, PDF, opens in a new tab |
| Semax (strength not stated)Format: not stated in reportPrinted sample: SemaxLot SEM31226Microbiology and endotoxin |
Microbiology only. No chemical identity, purity, assay or labelled quantity. ScanRDI entry states No Method Suitability on file. Additional tests & notesScanRDI sterility Pass; USP 85 endotoxin <2 EU/mL, limit 875 EU/mL, Pass No Method Suitability on file. No exact strength, purity or content established. | Eagle Analytical Services IncETX-260401-0327Microbiology laboratory reportPrint date: Named client: FAWC The report does not establish an exact labelled quantity or formulation. | Open full report ↗ for Semax, PDF, opens in a new tab |
| TB-500 (strength not stated)Format: not stated in reportPrinted sample: TB-500Lot TB1210Microbiology and endotoxin |
Microbiology only. No chemical identity, purity, assay or labelled quantity. ScanRDI entry states No Method Suitability on file. Additional tests & notesScanRDI sterility Pass; USP 85 endotoxin <2 EU/mL, limit 875 EU/mL, Pass No Method Suitability on file. No exact strength, purity or content established. Filename lot is TB12110, but printed lot is TB1210; mismatch retained. | Eagle Analytical Services IncETX-260402-0209Microbiology laboratory reportPrint date: Named client: FAWC The report does not establish an exact labelled quantity or formulation. | Open full report ↗ for TB-500, PDF, opens in a new tab |
How to read these results
Purity and measured content are different results. A high purity percentage does not establish the amount in a vial, and an endotoxin result is not a sterility result. Values and units above are transcribed from the named laboratory report; unreported measurements stay marked as not reported.
A supplier report applies when the exact compound, quantity, format and supplied lot match. A vial report does not verify a nasal formulation or another strength. Read the complete original for its methods, sample identity, limits and scope.
These links preserve the complete originals and laboratory/client details so the report can be checked. They do not constitute an independent HeartPep retest or confirmation of the issuer’s authenticity.
Order-lot certificates
Reports matched to the exact regional product and a supplied lot are kept separately from general supplier references.
No order-lot certificates published yet. Open the batch finder
0 published records
Reports will appear here as they are published.
A catalogue listing does not mean a batch report has been published.
Ask about batch documentation →What does a certificate establish?
A report applies to its named product and batch. A published link is not an independent HeartPep retest or a guarantee of sterility or suitability for human use. Match it to the lot proposed for supply.