US documentation
Lab results & certificates.
Search reported measurements and original documents by product, lot or report number. See how to match a lot number.
45 latest supplier reports
Latest available reports from our US supplier for each sample specification and test panel, newest first. Printed sample labels are retained where the wording differs. These reports have not been matched to a lot allocated to a HeartPep order.
Showing related supplier reports for GHK-Cu. Compare the exact quantity, format and lot in the document.
4 of 45 supplier reference reports
| Sample / lot | Reported results | Report details | Original document |
|---|---|---|---|
| GLOW 70 mg totalFormat: not stated in reportPrinted sample: GLOW 70MGLot KIZN072426Purity, content and additional panels |
RP-HPLC purity; HPLC potency, LC-MS identity and the additional sample tests stated in the report. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesIdentity Verification (LC-MS): GHK-Cu + BPC-157 + TB-500; pH (Probe): 6.21 (specification 5.0 – 8.0); Water Activity (Probe): 0.4010 aw; Endotoxin (LAL): Pass (specification ≤ 0.05 EU/mg); Sterility (USP <71>): Pass (specification No Growth); Total Yeast & Mold (USP <61>/<62>): Pass (specification Within Limits); Residual-solvent panel: listed results ND; heavy-metal panel: arsenic, cadmium, lead and mercury ND. Both panels marked PASS ND means not detected under the stated method limits, not zero concentration. Individual solvent and metal results/LOD/LOQ/action limits are reported in µg/g. These panels do not establish human-use suitability. Component amounts follow the component order printed in the original report. The single RP-HPLC purity value is reported for the tested blend; no separate component-purity minimum is stated. | Optiq Health Labs, LLC0324.OPT.260729-R1Certificate of analysisIssued/report date: Named client: Wholesale Peptide Supply | Open full report ↗ for GLOW 70MG, PDF, opens in a new tab |
| GHK-Cu 100 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.05 EU/mg, limit 3.50 EU/mg, Pass | Accurate Test LabsATL-37528Laboratory analysis reportCompleted date: Named client: Wholesale Peptide Supply | Open full report ↗ for GHK-CU 100MG, PDF, opens in a new tab |
| GHK-Cu 50 mgFormat: not stated in reportLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): analyte purity percentage and a distinct mg/unit content measurement. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.10 EU/mg (report limit 7.00 EU/mg; Pass) Sample label GHK-CU 50MG, quantitative result77.75mg/unit. Preserve both without assuming the marketed50mg label is independently verified by this result. The analyte row reports 99.784% while the displayed Total Purity summary rounds to 99.78%. Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37542Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply The sample label says 50 mg; the report lists 77.75 mg/unit. This discrepancy needs clarification before using it as batch evidence. | Open full report ↗ for GHK-CU 50MG, PDF, opens in a new tab |
| KLOW 80 mg totalFormat: not stated in reportPrinted sample: KLOW 80mgLot FLL-0629Purity, content and endotoxin |
Peptides panel (TM-13): total purity summary and individual analyte amounts in mg/unit. Component purity figures are mixture proportions, not separate 99%-purity claims. Additional panels are sample-specific; details and limits remain in the original PDF. Additional tests & notesEndotoxin 0.01 EU/mg (report limit 35.00 EU/mg; Pass) Endotoxin result applies to the tested sample and is not a sterility result. | Accurate Test LabsATL-37523Laboratory analysis reportCompleted date, not date tested: Named client: Wholesale Peptide Supply | Open full report ↗ for KLOW 80mg, PDF, opens in a new tab |
How to read these results
Purity and measured content are different results. A high purity percentage does not establish the amount in a vial, and an endotoxin result is not a sterility result. Values and units above are transcribed from the named laboratory report; unreported measurements stay marked as not reported.
A supplier report applies when the exact compound, quantity, format and supplied lot match. A vial report does not verify a nasal formulation or another strength. Read the complete original for its methods, sample identity, limits and scope.
These links preserve the complete originals and laboratory/client details so the report can be checked. They do not constitute an independent HeartPep retest or confirmation of the issuer’s authenticity.
Order-lot certificates
Reports matched to the exact regional product and a supplied lot are kept separately from general supplier references.
No order-lot certificates published yet. Open the batch finder
0 published records
Reports will appear here as they are published.
No published report is currently shown for GHK-Cu 50 mg · Nasal spray.
Ask about batch documentation →What does a certificate establish?
A report applies to its named product and batch. A published link is not an independent HeartPep retest or a guarantee of sterility or suitability for human use. Match it to the lot proposed for supply.